Specifications
| Model | 5707 |
|---|---|
| Supplier | Biomed |
| Category | Ventilators |
| Parameter | Value |
| Display | Size: 12.1 inch TFT color touch screen Resolution: 1280×800 Screen tilt adjustable within 15 degrees |
| Parameter | Value |
| Non-invasive Ventilation | P-AC, P-SIMV, CPAP /PSV, DuoVent, APRV, PSV-S/T, |
| Invasive Ventilation | V-AC, P –AC, V-SIMV, P-SIMV, PRVC, CPAP/PSV, DuoVent, APRV, PRVC-SIMV, VS. |
| High Flow Ventilation | High Flow O2 |
| Parameter | Value |
| O2 Concentration % | 21%~100% |
| TV (tidal volume) | Adults: 100~2200 ml Children: 20-300 ml |
| f (respiratory rate) | Adults/children: 1~100 breaths/min |
| f-SIMV (frequency of machine breaths) | 1~60 breaths/min |
| I | E (inhalation to exhalation ratio): 1:10~4:1 |
| T-insp. (inspiratory time) | Adults/children: 0.1~10 s |
| T-slope | Adults/children: 0~2 s |
| T-high | 0.2~30 s |
| T-low | 0.2~30 s |
| Timax | 0.20 ~ 15.00 s |
| T-pause | 5~60%, Off |
| △ P-insp. | Adults/children: 5~85 cмH2O |
| △ P-supp. | 0~85 cmH2O |
| P-high | Adults/children: 0~80 cмH2O |
| P-low | Adults/children: 0~80 cмH2O |
| PEEP (positive end-expiratory pressure) | Adults/children: 1~50 cмH2O, Off |
| F-trigger | Adults/children: from 0.5 to 15 l/min |
| P-trigger | From -10 to -0.5 cмH2O |
| Exp% | Auto, 10%~85% |
| Parameter | Value |
| TV-apnea | Adults: 100~2200 ml/ Children: 20-300 ml |
| △ P-apnea | Adults/children: 5~80 cмH2O |
| f-apnea | Adults/children: 1~80 breaths/min |
| T-insp.Apnea | 0.2~10 s |
| Parameter | Value |
| Sigh Function | On, Off. |
| Sigh Interval | 20 s~180 min |
| Sigh Cycle | 1~20 |
| △ int.PEEP | 0~45 cmH2O |
| Parameter | Value |
| Tube Type | endotracheal and tracheotomical |
| Tube ID | Adult: 5,0 - 12,0 mm Pediatric: 2,5 - 8,0 mm |
| Compensation | 0 -100 % |
| Compensation Switch | On, Off. |
| Parameter | Value |
| Airway Pressure Range | Ppeak, Pplat, Pmean (-20 – 120 cmH2O) |
| PEEP | 0–120 cmH2O |
| TVi | 0–4000 ml |
| TVe | 0–4000 ml |
| TVe spn | 0–4000 ml |
| Respiratory Rate Range | ftotal, fspn, fmand (0–200 breaths/min) |
| Minute Volume Range | MV, MVspn, MVleak (0–100 l/min) |
| Airway Resistance | Rinsp; Rexp 0~600 cmH2O/l/s |
| Compliance | Cstat, Cdyn (0 - 300 ml/cmH₂O) |
| Oxygen Supply (FiO2) | 15 - 100 % |
| WOB (Work of Breathing) | 0 - 100 J/min. |
| RCexp (Expiratory Time Constant) | 0 - 10 s |
| Curves (Graphical Signals) | Pressure-time, Flow-time, Volume-time |
| Parameter | Value |
| P0.1 (100 ms Occlusion Pressure) | -20 - 0 cmH2O |
| NIF (Maximum Negative Inspiratory Pressure) | -45 - 0 cmH2O |
| RSBI (Rapid Shallow Breathing Index) | 0 - 999 1/(L•min) |
| Parameter | Value |
| On-Screen Display | Pulse rate (PR), SpO2 value, SpO2 graphical curve |
| SpO2 Measurement Range | Masimo SpO2: 1–100 % |
| SpO2 accuracy | Masimo SpO2: in the range of 70–100% measurement accuracy for adults/children is ± 3% without motion; in the range of 1–69%, measurement accuracy is undefined. |
| Respiratory Rate Measurement Range | Masimo SpO2: 25–240 bpm |
| Respiratory Rate Measurement Accuracy (No Motion) | Masimo SpO2: 25-240 bpm - error is ±3 bpm |
| Perfusion Index | Masimo SpO2: measurement range: 0.02–20 %, |
| Data Update Period | 1s. |
| Signal Quality Index (SIQ) Display Function | Masimo SpO2 supports SIQ function |
| Parameter | Value |
| Type | Tabular, graphical |
| Memory | 72 h |
| Trend Data | Monitoring parameters, parameter settings (ventilation mode and parameter settings) include event parameters and alarm signals related to trigger time. |
| Parameter | Value |
| Event Log | Up to 8000 event logs can be saved, including alarm logs and operation logs. The alarm log contains alarm event parameters and parameter signals related to alarm trigger time. |
| Frozen Waveform Review (Freeze Frame Function) | During freeze, you can view the last 30 historical signals by moving the screen or turning the knob. |
| Freeze Cycle Review | Up to 5 reference loops can be saved. |
| Parameter | Value |
| O2 Concentration | 21 - 100 % |
| O2 Flow | 2 - 60 L/min |
| Parameter | Value |
| Gas Type | Air, O2 |
| Operation from high-pressure oxygen source | Pressure: 280 to 600 kPa / 2.8 to 6.0 bar; Flow: ≥ 120 L/min (STPD) Connector: NIST or DISS |
| Operation from low-pressure oxygen source | Pressure: <100 kPa / 1 bar Flow: 15 L/min (STPD) Connector: quick connect CPC |
| Air supply | Integrated turbine (built-in) |
| Parameter | Value |
| Peak flow rate | ≥ 210 L/min |
| Nebulizer connector | Flow rate: 6 L/min~9 L/min |
| Protective breathing pressure | ≤ 12.5 kPa |
| External connector on the inhalation side | Coaxial conical connector 22 mm/15 mm |
| Sterilization | Sterilizable parts quick-change |
| Compliance with regulatory requirements | EN ISO5356-1:2004 |
| Parameter | Value |
| External connector on the inhalation side | Coaxial conical connector 22 mm/15 mm |
| Sterilization | Sterilizable parts quick-change |
| Compliance with regulatory requirements | EN ISO5356-1:2004 |
| Parameter | Value |
| Compliance | Single-use adult circuit (including inhalation safety valve, single-use adult breathing tube, water collection cup, exhalation valve): ≤ 4 ml/cm water column; Reusable adult circuit (including inhalation safety valve, reusable adult breathing tube, water collection cup, exhalation valve, Y-joint): ≤ 2 ml/cm water column; Pediatric single-use circuit (including inhalation safety valve, pediatric single-use breathing tube, water collection cup, exhalation valve): ≤ 2 ml/cm water column; Pediatric reusable circuit (including inhalation safety valve, pediatric reusable breathing tube, water collection cup, exhalation valve, Y-joint): ≤ 2 ml/cm H2O; |
| Inhalation resistance | ≤ 6 cm H2O at a flow rate of 60 l/min (adult); ≤ 6 cm water column at a flow rate of 30 l/min (pediatric); |
| Exhalation resistance | ≤ 6 cm H2O at flow rate 60 L/min (adult); ≤ 6 cm H2O at flow rate 30 L/min (pediatric); |
| Parameter | Value |
| Pressure monitoring range | -20~120 cm H2O |
| Safe system pressure | In ventilation state: ≤ 125 cm H2O In non-ventilation state, or power failure or gas source failure (<0.12 MPa): ≤ 14 cm H2O |
| Parameter | Value |
| Power supply from AC mains | Voltage: 100 - 240 V Frequency: 50 / 60 Hz Current consumption: 0.5 - 1.2 A |
| Power supply from built-in battery | Quantity: One battery (two - optional) Type: lithium-ion Voltage: 14.4 V Capacity: 6700 mAh Recharge time: 4.5 hours (for one battery) Usage time: 140 minutes under standard working conditions (for two batteries – 280 minutes) |
Ventilators
Mechanical Ventilator V3
Model: 5707
- More than 20 years in medical supply
- Specifications, availability and document checks
- Nova Poshta, Delivery or coordinated transport across Ukraine
- Payment by bank transfer; returns under applicable law
Product description
V3 is a turbine-based respiratory support platform capable of handling various scenarios, including bedside ventilation (long-term / short-term) and ventilation during intra-hospital transport. V3 provides comprehensive ventilation modes (invasive, non-invasive ventilation) covering critical and subcritical respiratory therapy for adults and children (with weight >3kg). Warranty 24 months. Features: Standard configuration · Main unit with a 12.1 inch touchscreen, TFT, color display, screen tilt adjustable within 15 degrees. · Mobile stand on four wheels. · Ventilation modes: v Non-invasive P-AC pressure-controlled ventilation. P-SIMV synchronized intermittent mandatory ventilation with pressure control. CPAP /PSV positive continuous airway pressure. DuoVent two-level ventilation with continuous positive airway pressure. APRV ventilation with variable airway pressure. PSV-S/T pressure support ventilation for spontaneous breathing / timed. v Invasive V-AC volume-controlled ventilation. P-AC pressure-controlled ventilation. V-SIMV synchronized intermittent mandatory ventilation with volume control. PRVC volume control with pressure regulation. CPAP/PSV elevated continuous airway pressure / pressure support ventilation. APRV ventilation with variable airway pressure. PRVC-SIMV synchronized volume control with pressure regulation. VS volume support with pressure regulation depending on patient respiratory mechanics. · High-flow oxygen therapy High Flow O2. · SpO2 monitoring (blood oxygen saturation). · PR monitoring (pulse rate). · Connector (interface) for external CO2 module suitable for capnography parameter measurement. The intuitive device interface facilitates its setup and enhances operational efficiency in any clinical situation; medical staff can easily master it without complex training. The standard ventilator configuration supports operation in invasive ventilation (10 modes) and non-invasive ventilation (6 modes), allowing work with patients in both long-term and supportive ventilation. A wide range of settings and limits ensures high safety, and intelligent ventilation modes prevent patient injury. The built-in high-performance turbine (flow rate up to 210 l/min, service life 20000 hours) eliminates the need to connect to an external air compressor or centralized high-pressure air source. The device can operate from oxygen sources with high or low pressure. The oxygen sensor allows precise control of O2 concentration in the breathing mixture. The built-in high-capacity battery provides autonomy when the external power source is off or during intra-hospital patient transport. Usage duration: more than 2 hours from one battery, with two batteries installed more than 4 hours. The carefully designed device control system ensures a stable and accurate flow to the patient. The mobile cart enables transportation within the medical facility. The inhalation and exhalation valves are installed and removed without tools, suitable for sterilization by high temperature and high pressure in an autoclave. The IntelliSynTec function dynamically optimizes the trigger threshold using an adaptive algorithm according to the patient's lung characteristics. The Sigh function provides additional breaths. PV Tools instruments. The PulmoView function models lung expansion and contraction in real time, monitors important parameters such as compliance and airway resistance. This helps assess lung condition in real time and evaluate the effect of patient treatment. Extubation readiness indicators assist medical staff in determining the optimal time for extubation. The intensity of the patient's spontaneous breathing can be assessed based on measured values to determine whether the endotracheal tube can be removed and whether the patient requires reintubation. Monitoring of physiological parameters: SpO2 (blood oxygen saturation); PR (pulse rate); capnography parameters FiCO2/EtCO2 (CO2 concentration on inhalation/exhalation, measured in main or side stream). The ventilator memory is designed to store: graphical/tabular trend data on operating parameters for 72 hours for one patient, a log of 8000 events (alarm events and user events)