Medical equipment and rehabilitation products
✉ vbagniy@gmail.comMon–Fri: 09:00–18:00 · Sat–Sun: closedDelivery throughout UkraineEN
Home›Catalog›Electrotherapy›Device «Radius-01 Inter» (mode: IT)
Device «Radius-01 Inter» (mode: IT)
Free delivery on orders over UAH 7,000

Specifications

Model3208
SupplierBiomed
CategoryElectrotherapy
Patient current in IT mode, mA0 - 40
Protection trigger threshold in IT mode, mA40
Number of channels2
Information displayDigital LCD
Power consumption, max, W30
Continuous operating time, h8
Overall dimensions, mm270 x 190 x 90
Power supply voltage, V198 - 242
Device weight, kg2,5
Temporarily unavailable · Biomed

Electrotherapy

Device «Radius-01 Inter» (mode: IT)

Free delivery on orders over UAH 7,000

Model: 3208

47,849 UAH
This model is currently unavailable

Browse available alternatives in this category or call us for help selecting a replacement.

View alternatives →
Why customers choose MEDTECH UA
  • More than 20 years in medical supply
  • Specifications, availability and document checks
  • Nova Poshta, Delivery or coordinated transport across Ukraine
  • Payment by bank transfer; returns under applicable law
Consultation:+38 (067) 611-29-76+38 (099) 742-06-86Mon–Fri: 09:00–18:00 · Sat–Sun: closed

Product description

Designed for rehabilitation after diseases and injuries. Its action is based on therapeutic effects of interference currents according to Nemec - interference therapy. The "Radius-01 Inter" device is intended for rehabilitation after diseases and injuries. Its action is based on therapeutic effects of interference currents according to Nemec - interference therapy. Interference current therapy (interference therapy) is based on introducing medium-frequency currents (about 4000 Hz) into painful areas of the patient's body in two independent circuits using four electrodes. The current frequencies in both circuits differ by no more than 100 Hz. As a result of the superposition of these two currents in the patient's body, a biologically active interference current with a frequency of 0 - 100 Hz arises in the disease focus. The frequency of the interference current corresponds to the difference between the frequencies of both component currents. Medium-frequency interference currents have a distinct, rapidly acting analgesic effect, improve the functional state of the neuromuscular system and peripheral circulation, contribute to vasodilation, acceleration and improvement of metabolism. The interference method allows the use of high-intensity currents (30-50 mA) in each circuit without the risk of burns under the electrodes and allows reaching and covering disease foci located deep in the body, with painless procedures. Unlike other currents (e.g., diadynamic DDT), interference currents do not cause skin irritation under the electrodes, so they are successfully used in pediatric physiotherapy and rehabilitation. Applications for diseases: - gastrointestinal tract (chronic colitis, gastroduodenitis, biliary dyskinesia, constipation, etc.); - respiratory organs (chronic bronchitis, bronchial asthma, recovery from pneumonia, etc.); - genitourinary system (kidney stone disease, chronic prostatitis, adnexitis, algomenorrhea, etc.); - joints (arthroses, injuries, contractures, polyarthritis, etc.); - peripheral nervous system (neuropathies, neuralgias, radiculitis, plexitis, ganglions, sympathoganglions, etc.); - spine (osteochondrosis, posture disorders, spinal injuries, Bechterew's disease, etc.); - vessels (obliterating endarteritis, atherosclerosis of limb vessels, etc.); - sports injuries; - cosmetology for overweight, cellulite, skin aging. Operational capabilities: • current information is displayed on a graphic LCD with backlight; • automatic operating mode with variable frequency in ranges: (0-10; 25-50; 50-100; 90-100; 0-100) Hz; repetition period (15 + 1,5) seconds; • mode for selecting a constant interference frequency in the range: (0-100) Hz; • automatic current balance in both channels; • visual observation of current waveforms on the graphic LCD; • at the end of the procedure, the current regulator always automatically returns to zero state

RELATED PRODUCTS

More in Electrotherapy

View all →