Specifications
| Model | sku-2585 |
|---|---|
| Supplier | Meditor |
| Category | Glucometers and test strips |
| Compatibility | Gold Heaco AQ Plus glucometer |
| Enzyme | FAD-GDH |
| Sample type | capillary, venous, arterial blood |
| Minimum sample volume | 0.8 µL |
| Measurement range | from 1.1 to 33.3 mmol/L; Strips do not require coding; Package contents |
| Packaging | 50 pcs |
Glucometers and test strips
Test strip for Heaco Gold AQ Plus glucometer (50 pcs)
Model: sku-2585
- More than 20 years in medical supply
- Specifications, availability and document checks
- Nova Poshta, Delivery or coordinated transport across Ukraine
- Payment by bank transfer; returns under applicable law
Product description
Gold AQ Plus blood glucose test strips With patented LUNULA nano technology designed for use with the Gold AQ Plus glucometer. The test strips allow measurement of glucose content in fresh capillary whole blood, venous blood, or arterial blood. The Gold AQ Plus blood glucose test strip is intended for in vitro diagnostic use by people with diabetes and does not require coding. Thanks to optimization of the number and arrangement of micropores, the patented LUNULA nano technology significantly improves testing speed and quality. Advantages of test strips with LUNULA nano technology: 99.99% gold electrode, conductivity 1400 times higher than carbon electrode. Exceptional electrochemical properties and high corrosion resistance. Ability to accurately determine blood sample temperature, HCT, and ambient temperature, and automatically correct deviations in results caused by these factors. Principle of operation description: The glucose test operates based on the enzyme FAD-GDH. Electric current arises from the chemical reaction between glucose and reagents on the strip electrode surface. For testing, a drop of blood or control solution is applied to the strip tip by capillary action. Glucose reacts with chemical elements of the strip, generating electrons that create current. The glucometer detects this current and converts it into a glucose level result. Storage conditions and shelf life: Store at temperatures from 1°C to 30°C. For convenience, record the date of first opening on the label. Instructions for use: Thoroughly wash and dry the puncture site. Take one test strip from the vial and immediately close it. Insert the strip into the glucometer port; the device will turn on automatically. Obtain a drop of blood for testing. Touch the test strip to the blood drop and allow it to absorb. The result will then display on the screen. After testing, press the eject button to discard the used strip into the appropriate waste container.